Pc1832 programming manual
Doing so may cause problems in the function of your alarm system. Even though your system comes factory defaulted; we suggest that you default the system just to pc1832 programming manual sure you have a clean slate to work with.
Forever nerd and SaaS entrepreneur. Intrigued by software engineering, software as a business and aviation. I purchased the IT board and then decided I wanted to expand it a bit further to include more zones. I quickly realized I could use the IT board and some time to systematically determine the installer code but the time spent on that would be spent only because I had some concerns regarding reprogramming it. I decided to reprogram it myself and here are my notes for anyone attempting to program or even reprogram their own DSC alarm. The process is incredibly straight forward with only a few caveats. I have another system with PK keypads and they are great.
Pc1832 programming manual
.
You will also want to have the ESN of any wireless device also written down next to the proper zone.
.
Table Of Contents. Table of Contents. Quick Links. This manual contains information on limitations regarding product use and function and information on the limitations as to liability. The entire manual should be carefully read. Previous Page. Next Page. Page 7: Additional Devices PC v1.
Pc1832 programming manual
.
Briggs and stratton power washer
A: Initially I thought I had the jumpers wrong on the system but it turns out they were in a zero partition and using codes , and fixed that question above. At each keypad I enrolled each one one by one. Enter each number as indicated on the sticker. However, now I am decorating it with a Raspberry Pi. Q: How come zones 1 - 8 are working but zones 9 - 24 are not working? I decided to reprogram it myself and here are my notes for anyone attempting to program or even reprogram their own DSC alarm. Enter section and enter 05 05, system will beep 3 times. You have to listen for the beeps. You select the letter you want by continuously pressing the same button until your desired letter or number appears. A: That is because they are in the wrong partition and have to be moved into partition one. Version 4. You cannot place any wireless device on a zone set that is shared with any hardwired zone. Skip this step if you are not using the PGM outputs for your smoke detectors Press Since you did not use resistors, we need to turn off option 6 and we need to make sure option 1 is on. You will go over the zone number in the programming section and turn on toggle option 8 on. Here is a Sample Alarm Kit we will use for an example :.
.
The in the First Option Code group we need to make sure option 1 is on. Press Since you did not use resistors, we need to turn off option 6 and we need to make sure option 1 is on. You will then enter the zone number for the wireless device you want to enroll. You will also want to have the ESN of any wireless device also written down next to the proper zone. After entering the Installer Code we will now be in the Programming Section. Press to change your installer code from the default setting of Example: 1, 2, 3, 4, 5 would be zones 9, 10, 11, 12, Q: How come zones 1 - 8 are working but zones 9 - 24 are not working? You must keep your wireless zones somewhere in the first 32 zones. If also enrolling wireless, each wireless device is a zone, with the exception of the key fobs.
In it something is. Thanks for an explanation.