rexroth indradrive error codes

Rexroth indradrive error codes

When an error flashes on the control panel, you can clear the error message by resetting or using the Esc button. However, if the error state still exists, the error message will immediately begin flashing again.

At the core of many manufacturing and industrial tasks is the Rexroth IndraDrive. But, if you stumble upon fault codes in your drive interface without proper understanding, it can be intimidating. We can make things easier by breaking down frequently observed fault codes, explaining their possible origins, and providing solutions. In the event of such errors, the drive's safety measures get disabled, drive torque is immobilized, and following a diagnostic message display, the power is terminated. It's imperative to reboot the system to restore its operation. Here are some specific error instances:. If the problem remains, drive replacement might be required.

Rexroth indradrive error codes

Table Of Contents. Table of Contents. Quick Links. LSA Control S. Ronda Narciso Monturiol y Estarriol, Previous Page. Next Page. Offenders are liable for the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design DIN When a diagnostic message of the "error" category occurs, the corresponding diagnostic message number is stored in the P, Error number parameter. Page 20 Rexroth IndraDrive Basics on Device Diagnosis The diagnostic message for the non-fatal error "Excessive deviation", for example, has the following structure: F Excessive deviation diagnostic text diagnostic message number Fig.

Wow, that's a big list! March 14,PM.

Obsolete industrial electronics forum is still alive and well, just undergoing some maintenance and more anti spam stuff, stand by for a better experience. We use both first and third-party cookies on this website. Cookies are small text files, stored on your computer that help provide advertising and give you the best experience while visitng our site. By continuing to use the site without changing settings, you are agreeing to our use of cookies. Read our complete cookie policy.

At the core of many manufacturing and industrial tasks is the Rexroth IndraDrive. But, if you stumble upon fault codes in your drive interface without proper understanding, it can be intimidating. We can make things easier by breaking down frequently observed fault codes, explaining their possible origins, and providing solutions. In the event of such errors, the drive's safety measures get disabled, drive torque is immobilized, and following a diagnostic message display, the power is terminated. It's imperative to reboot the system to restore its operation. Here are some specific error instances:.

Rexroth indradrive error codes

When an error flashes on the control panel, you can clear the error message by resetting or using the Esc button. However, if the error state still exists, the error message will immediately begin flashing again. If, for example, you see error code F, Incorrect Ethernet configuration, you will have to correct the ethernet configuration before you can continue using your IndraDrive C. The intelligent operating panel has a programming function which supports device swap without a PC. Digital inputs and outputs as well as analog input on board. In line with newer Rexroth lines, the IndraDrive C is energy efficient and features drive-integrated safety technology. We can provide a manual for IndraDrive C. Just use our Manual Request form. Need more than a manual? We offer phone and field support, factory repair, and factory reman.

Sparefoot

The execution of the command was aborted. At the core of many manufacturing and industrial tasks is the Rexroth IndraDrive. Ronda Narciso Monturiol y Estarriol, A special pulse is put on the wire to verify that the signal is not "jumped" by someone trying to bypass it. Several of these errors will require replacement of the control section, but further reference to individual errors is required. Cause Remedy In the case of incremental measuring systems, check If the error message is generated by a technology function made available by Bosch Rexroth, the causes and remedies are contained in the description of the technology function. Cause Remedy Common IndraDrive fault codes and descriptions. By continuing to use the site without changing settings, you are agreeing to our use of cookies. Clearing the issue and reestablishing position data reference is suggested. Phone Number.

Table Of Contents.

Page A Phase Synchr. You can contact your local Rexroth support office for help with a repair. Note: The drive controllers may only be used with the accessories and parts specified in this document. Below are several specific examples:. I don't remember the details, But I believe it had to do with Byte swapping. Cause: There was an attempt to clear the F Enc. Page F Actual Pos. Toll Free: International: Cause: By the encoder selection in S, Homing parameter an absolute measuring system was selected. With one exception, these errors all have to do with external control signals not meeting the requirements of the drives double MDT or MST failures, Communication buss failures. The input values required for the model calculation are checked for plausibility.

2 thoughts on “Rexroth indradrive error codes

Leave a Reply